STO200-02 Typical Applications SDH/SONET ATM WLL Measurement Equipment TCXO Features Meets Stratum III Overall Stability Very Low Aging Standard Surface Mount Package Frequency Frequency stabilities Parameter 12.800 MHz Frequency stability Operating temp range vs. operating temperature range Parameter < 370 ppb Value 0 ... +70C Condition Initial tolerance vs. supply voltage vs. load change st vs. aging / 1 . year vs. aging / 20 year Over all stability Meets Stratum III requirement < 1 ppm < 0.1 ppm < 0.1 ppm < 500 ppb < 3 ppm < 4.6 ppm @ 25C static static RF output Parameter Value Condition Signal Load Rise and Fall time Duty cycle HCMOS 15 pF 5 % < 5 ns 40/60 % Note 1 @ 15pF & 10 to 90% @ Vs/2 Supply voltage Parameter Value Condition Supply voltage (VS) Input current 3.3 V 5 % < 10 mA Value @ 25C Condition Additional parameters Parameter Phase Noise Weight Operable temperature range Storage temperature range Processing & Packing -60 dBc/Hz -90 dBc/Hz -120 dBc/Hz -140 dBc/Hz -145 dBc/Hz -150 dBc/Hz <9g -20 ... +70C -40 ... +90C handling&processing note 1 10 100 1 10 100 Hz Hz Hz kHz kHz kHz Note 2 Corning Frequency Control * Worldwide Data Book 2001 v1.2 .2001-11-20 Corning Frequency Control Inc. * 100 Watts Street * Mt. Holly Springs, PA 17065 * Tel 1-717-486-3411 * Fax 1-717-486-5920 * www.corningfrequency.com Corning Frequency Control GmbH & Co. KG * Landstrasse * D-74924 Neckarbischofsheim, Germany * Tel +49-7268-801-0 * Fax +49-07268-801-281 * www.corningfrequency.de 1/2 STO200-02 Enclosure Typ Drawing G 185 B TCXO 7 6 5 4 G185 H =11,3 ; G185 Standard 2,5 2,5 1 2 3 H 0,2 S Auflage flache 7,620,1 17,8 0,1 22 0,2 all units in mm 0,1 S Pin Connections Pin 1 Pin Pin Pin Pin Pin Pin 2 3 4 5 6 7 I.C. I.C Vs (supply voltage) HF-Output I.C. I.C. GND Example: Order: Ordering Code Model STO200-02.. STO200-02 Frequency 12M8000 Note 1 2 can drive TTL, ACMOS and CMOS Typical values @ 12.80 MHz Unless otherwise stated all values are valid after warm-up time and refer to typical conditions for supply voltage, frequency control voltage, load, temperature (25C) Subject to technical modification; Not all options and codes are available at all Frequencies Corning Frequency Control * Worldwide Data Book 2001 v1.2 .2001-11-20 Corning Frequency Control Inc. * 100 Watts Street * Mt. Holly Springs, PA 17065 * Tel 1-717-486-3411 * Fax 1-717-486-5920 * www.corningfrequency.com Corning Frequency Control GmbH & Co. KG * Landstrasse * D-74924 Neckarbischofsheim, Germany * Tel +49-7268-801-0 * Fax +49-07268-801-281 * www.corningfrequency.de 2/2 25,4 0,2 |
Price & Availability of STO200-02 |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |